beautypg.com

AMETEK Compact i/iX Series User Manual

Page 121

background image

User Manual

Compact i/iX Series

AMETEK Programmable Power

California Instruments

121

FREQUENCY TRANSIENTS (Group 1 and A(CF) only)

Seq. No

Frequency

Time

1

400

5 Minute

2

440

150msec

3

420

1.5sec

4

400

5Sec.

5

350

150msec

6

380

1.5sec

7

400

5Sec.

Table 9-6: Normal Frequency Transient Sequence

This test applies to Group1 and A(CF) only. The output voltage is set to Vnom (115 V) while the
frequency is changed per the sequence listed in Table 9-6. The test will cycle 5 times starting from
sequence 2. Steps 3 and 6 apply to A(CF) only.

FREQUENCY VARIATION (Group2 / A(NF) and Group3 / A(WF) only)

Seq. No

Initial Frequency

Slew rate

Final Frequency

Group2

Group3

Hz/Sec

Group2

Group3

1

360

360

100

650

800

2

650

800

100 or 200

360

360

3

360

360

Pause 5 sec

360

360

Table 9-7: Normal Frequency Variation Sequence

This test will apply to Group2/A(NF) and Group3/A(WF) only. . The output voltage is set to Vnom (115
V) while the frequency is set to 360Hz for 5 minutes. The frequency is slowed per the sequence listed
in Table 9-7. The test will cycle 3 times. The frequency will return to nominal after the test is
completed. Slew rates of 200Hz apply to RTCA2 only.