beautypg.com

StorCase Technology Fibre-to-SCSI Single RAID User Manual

Page 34

background image

22

Configuration

StorCase Technology, Inc.

S10C100 User's Guide - Rev. A01

8.

If the Number of Spares screen displays, enter the number of spares to add and press

Enter.
This creates dedicated spares that can only be used in this array. A dedicated spare

drive will not be available for any other use (refer to section "Managing Spares" for

further information).
If no spare is desired, simply enter 0.
The Select Drives screen should now display (Figure 14).

9.

Select the drive to be used as a dedicated spare and press Enter.

NOTES: Only available drives (drives that aren't members of an array and are not assigned

as dedicated or pool spares) will be displayed. A drive is selected by highlighting

it and then pressing Enter. Each selected drive turns gray in the drive list. To skip

a drive, use the é or ê key.
A dedicated spare can be deleted from the array at any time (refer to section

"Deleting a Dedicated Spare" for further information).

If the array created is RAID 3, RAID 4, RAID 5, or RAID 50, the Chunk Size screen will

display (Figure 15).

Figure 15: Chunk Size Screen