background image

S10C100 User's Guide - Rev. A01

StorCase Technology, Inc.

Installation

7

Typical RAID Channel Configurations

NOTE:

When using the optional InfoStation I/O repeater modules, StorCase recommends the

use of Port A-1 & A-2 when configuring typical RAID channels (as shown in Figure

3B). In the special cases where extra length cables are required (up to 12m max-

imum), use Port B instead.

Figure 3A: Typical InfoStation RAID Module 2x4 Dual-Channel Configuration

(InfoStation Chassis with Standard I/O Modules)

NOTE:

Maximum 15 Disks per SCSI Channel (15 Disks x 4 channels = 60 Disks

To

tal)

IFS_RAID27FC

T

=Terminator

FC Host/Device 1

LoopBack or Cascade

LoopBack or Cascade
FC Host/Device 0

Disk Ch. 3

Disk Ch. 2

Disk Ch. 0

Disk Ch. 1