beautypg.com

Changing the additional saf-te board settings – StorCase Technology Fibre-to-SCSI Single RAID User Manual

Page 135

background image

S10C100 User's Guide - Rev. A01

StorCase Technology, Inc.

Configuration

123

Changing the Additional SAF-TE Board Settings

The user can change four (4) additional settings:

• Polling Interval - The interval (in seconds) that the controller polls the SAF-TE Board

for status changes (default is 5 seconds).

• Temperature Sensor Status - This controls whether the controller's onboard

temperature sensor provides temperature information to the host along with the en-

closure's temperature detected by the SAF-TE Board. Default is OFF (neither the

controller nor the enclosure is providing temperature information to the host).

• Slot Update Status (Slot Flags) - This controls whether the controller sends com-

mands to the SAF-TE Board to upbeat the status of each enclosure drive bay. Default

is ON (controller will request status updates from the enclosure).

• Enclosure Update Status (Global Flags)- This controls whether the controller

will send commands to the SAF-TE Board to update the overall status of the

enclosure. Default setting is OFF (controller will not request status updates from

the enclosure).

To change the SEP Settings:

1.

Select Configuration Menu from the System Menu and press Enter.
The Configuration Menu should now display (Figure 38).

2.

Select SEP Configuration and press Enter.
The SEP Configuration screen should now display (Figure 81).

3.

Select SEP Settings and press Enter.
The Poll Rate screen should now display (Figure 85).