Changing the additional saf-te board settings – StorCase Technology Fibre-to-SCSI Single RAID User Manual
Page 135
![background image](/manuals/742415/135/background.png)
S10C100 User's Guide - Rev. A01
StorCase Technology, Inc.
Configuration
123
Changing the Additional SAF-TE Board Settings
The user can change four (4) additional settings:
Polling Interval - The interval (in seconds) that the controller polls the SAF-TE Board
for status changes (default is 5 seconds).
Temperature Sensor Status - This controls whether the controller's onboard
temperature sensor provides temperature information to the host along with the en-
closure's temperature detected by the SAF-TE Board. Default is OFF (neither the
controller nor the enclosure is providing temperature information to the host).
Slot Update Status (Slot Flags) - This controls whether the controller sends com-
mands to the SAF-TE Board to upbeat the status of each enclosure drive bay. Default
is ON (controller will request status updates from the enclosure).
Enclosure Update Status (Global Flags)- This controls whether the controller
will send commands to the SAF-TE Board to update the overall status of the
enclosure. Default setting is OFF (controller will not request status updates from
the enclosure).
To change the SEP Settings:
1.
Select Configuration Menu from the System Menu and press Enter.
The Configuration Menu should now display (Figure 38).
2.
Select SEP Configuration and press Enter.
The SEP Configuration screen should now display (Figure 81).
3.
Select SEP Settings and press Enter.
The Poll Rate screen should now display (Figure 85).