ADLINK ND-6067 User Manual
Page 264
![background image](/manuals/733481/264/background.png)
262
Code
Input
Range
Data
Format
+Full
Scale
Zero
- Full
Scale
Displayed
Resolutio
n
00
±15mV
2’s Comp.
7FFF
0000
8000
1 LSB
01
±50mV
2’s Comp.
7FFF
0000
8000
1 LSB
02
±100mV
2’s Comp.
7FFF
0000
8000
1 LSB
03
±500mV
2’s Comp.
7FFF
0000
8000
1 LSB
04
±1V
2’s Comp.
7FFF
0000
8000
1 LSB
05
±2.5V
2’s Comp.
7FFF
0000
8000
1 LSB
06
±20mA
2’s Comp.
7FFF
0000
8000
1 LSB
07
Reserved
08
±10V
2’s Comp.
7FFF
0000
8000
1 LSB
09
±5V
2’s Comp.
7FFF
0000
8000
1 LSB
0A
±1V
2’s Comp.
7FFF
0000
8000
1 LSB
0B
±500mV
2’s Comp.
7FFF
0000
8000
1 LSB
0C
±150mV
2’s Comp.
7FFF
0000
8000
1 LSB
0D
±20mA
2’s Comp.
7FFF
0000
8000
1 LSB
Table 8-9 Analog Input Range and resolution
Code
Input Range
Thermocouple
Data
Format
Maximum
Minimum
Displayed
Resolution
0E
J (0
°C to 760°C)
2’s Comp.
7FFF
0000
1 LSB
0F
K (0
°C to 1000°C)
2’s Comp.
7FFF
0000
1 LSB
10
T (-100
°Cto400°C)
2’s Comp.
7FFF
E000
1 LSB
11
E (0
°C to 1000°C)
2’s Comp.
7FFF
0000
1 LSB
12
R (500
°C to 1750°C)
2’s Comp.
7FFF
2492
1 LSB
13
S (500
°C to 1750°C)
2’s Comp.
7FFF
2492
1 LSB
14
B (500
°C to 1800°C)
2’s Comp.
7FFF
238E
1 LSB
15
N (-270
°C to 1300°C)
2’s Comp.
7FFF
E56B
1 LSB
16
C (0
°C to 2320°C)
2’s Comp.
7FFF
0000
1 LSB
Table 8-10 Thermocouple Type ,Temperature Range and resolution
Example 2:
♦
Input Range is
±5 V
♦
Input is +1 Volts
Two’s complement hexadecimal: 1999
Example 3:
♦
Input Range is
±5 V
♦
Input is -2 Volts