beautypg.com

ADLINK ND-6067 User Manual

Page 220

background image

218

6.7.23 Set TTL Input Low Trigger Level

@Description

Set the TTL input low trigger level, for voltage level lower than this
value is recognized as logic low.

@Syntax

$(Addr)1L(ThData)

$

Command leading code.

(Addr)

Address ID (2-character)

1L

TTL input low trigger level command code.

(ThData)

The low trigger level for TTL input. The unit is 0.1 V
and its resolution is 0.1 V too. This value range from
0.1 to 5V, which is a 2-digit integer.

@Response

!(Addr)

or

?(Addr)

!

Command is valid.

?

Command is invalid.

(Addr) Address

ID.

@Example

User command:

$301L10

Response:

!30

Item Meaning

Description

$

(Leading Code)

Command leading code.

30

(Addr)

Address ID is 30H.

1L

Set TTL input low trigger level.

10 (ThData)

1

V

(6080)