beautypg.com

ADLINK ND-6067 User Manual

Page 177

background image

175

6.5.2 Read Synchronized Data

@Description

After a synchronized sampling command #** was issued, you
can read the input value that was stored in the addressed
module’s register and use same method to process other
module‘s data one by one.

@Syntax

$(Addr)4

$

Command leading code.

(Addr) Address

ID.

4

Read synchronized data.

@Response

ND-6050 module response :

!(Status)(DataOut)(DataIn)00

ND-6052 module response :

!(Status)(DataIn)0000

ND-6053 module response :

!(Status)(DataInH)(DataInL)00

ND-6054 module response :

!(Status)(DataInH)(DataInL)00

ND-6058 module response :

!(Status)(IOFlag)(DIn)(DataInA)(DataInB)(DataInC)

ND-6060 module response :

!(Status)(DataOut)(DataIn)00

or

?(Addr)

!

Command is valid.

?

Command is invalid.

(6050, 6052, 6053,

6054,6058, 6060)