Setting up external alarms, Ms 92 – Interlogix DVR 60 User Manual User Manual
Page 98
11BChapter 12: Configuring alarm settings
92
TruVision DVR 60 User Manual
notification options available are: Buzzer, TCP/IP notification, Alarm Out, and
Email.
9. Click
Apply
and then
OK
to save your changes and return to the Advanced
menu.
10. Copy these motion detection settings to other cameras, if required.
11. Click
Apply
and then Click
OK
to return to the Camera Management screen.
Setting up external alarms
The DVR can be configured to record when an alarm is triggered by an external
alarm device (for example, PIR detector, dry contacts…).
To set up external alarms:
1. Enter the Alarm Management menu by selecting
Alarms
in the main menu.
2. Under the Alarm Input tab, select the Alarm Input number of a camera and
click
Set
. The Alarm Settings screen displays.
3. Select the alarm input type in the Input Type box.
Options available include: Normally Opened (NO) and Normally Closed (NC).
4. Set up the rules for the alarm inputs to be triggered, such as the alarm
schedules and method of alarm notification.
Check the
Rules
box, and then click the
Set