USE OF THE USB PORT
12.1
Foreword
Through the USB port it is possible to make the following operation (from and in a text document):
-
upload and download of the configuration parameters
-
upload and download of the programs
-
download of the information relative to the HACCP alarms.
The upload / download procedures are allowed on condition that the firmware of the device of origin and the one of the
device (or the devices) of destination are coincident.
The procedures are guaranteed if using the EVCO USB peripheral EVUSB4096M.
12.2
Upload
and
download
of
the
configuration
parameters
To make the download of the configuration parameters operate as follows:
1.
Make sure the device is in the “stand-by” status.
2.
Insert an USB peripheral in the USB serial port; waith some seconds
3.
Press and release the key (1) to select “PARAMETERS DOWNLOAD”, then press and release the SET key (2):
it will automatically be started the writing (into the peripheral) of a document by name “param.bin” (containing
information about the configuration parameters); the writing procedure can take some seconds.
4.
To the end of the download remove the USB peripheral from the USB port.
To make the upload of the configuration parameters operate as follows:
5.
Make sure the device is in the “stand-by” status.
6.
Insert an USB peripheral in the USB serial port; make sure the peripheral contains the text document by name
“param.bin” (see point 3).
7.
Press and release the key (1) to select “PARAMETERS UPLOAD”, then press and release the SET key (2): it
will automatically be started the reading (from the peripheral) of the text document by name “param.bin”
(containing information about the configuration parameters); the reading procedure can take some seconds.