beautypg.com

7 temperature-controlled deep freezing and storage – EVCO EVCSR818P9EF User Manual

Page 31

background image

EVCO S.p.A.

Vcolor 818

| Installer manual ver. 1.1 | Code 144VC818E114

page 31 of 94

5.

Press and release the START/STOP key (1): the cycle will be started.

During blast chilling the device displays the temperature of the cabinet, the program name (if envisioned) and the time

passed since the start of blast chilling.

Operate as indicated to stop the cycle:

6.

Press and hold the START/STOP key 3 s.

Parameter r7 establishes the work set-point during blast chilling.

6.7

Temperature-controlled deep freezing and storage

The temperature-controlled deep freezing and storage cycle is divided into the following two phases:

-

deep freezing

-

storage.

On conclusion of a phase, the device passes automatically to the next.

Operate as indicated to start the cycle:

1.

Make sure the device is in the "on" status.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Press and release the key (1), press and release the key (2) and then press and release the key (3) and finally

press and release the key (4): the device will display the deep freezing end temperature and the work set-point

during deep-freezing.