During deep freezing the device displays the temperature of the cabinet, the program name (if envisioned) and the

duration of deep freezing.

Parameter r11 establishes the work set-point during storage.

6.10

Time-controlled soft deep freezing and storage

The time-controlled soft deep freezing and storage cycle is divided into the following three phases:

-

deep freezing soft phase

-

deep freezing

-

storage.

On conclusion of a phase, the device passes automatically to the next.

Operate as indicated to start the cycle:

1.

Make sure the device is in the "on" status.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Press and release the key (1), and then press and release the key (2): the device will display the duration of

deep freezing and the work set-point during deep-freezing.