5 time-controlled hard blast chilling and storage – EVCO EVCSR818P9EF User Manual
Page 28

EVCO S.p.A.
Vcolor 818
| Installer manual ver. 1.1 | Code 144VC818E114
page 28 of 94
During storage the device displays the temperature of the cabinet, the program name (if envisioned) and the duration
of blast chilling.
Parameter r10 establishes the work set-point during storage.
6.5
Time-controlled hard blast chilling and storage
The time-controlled hard blast chilling and storage cycle is divided into the following three phases:
-
blast chilling hard phase
-
blast chilling
-
storage.
On conclusion of a phase, the device passes automatically to the next.
Operate as indicated to start the cycle:
1.
Make sure the device is in the "on" status.
2.
Make sure that the keyboard is not locked and that no procedure is in progress.
3.
Press and release the key (1), press and release the key (2) and then press and release the key (3). the device
will display the blast chilling duration and the work set-point during blast chilling.
4.1
Press and release the MENU key and then press and release th key (4) or the key (5) to select the blast chilling
duration and the work set-point during blast chilling.