EVCO S.p.A.

Vcolor 818

| Installer manual ver. 1.1 | Code 144VC818E114

page 64 of 94

P5

0

1

- - - -

1

enabling the condenser probe

1 = yes

P8

0

1

- - - -

1

backlight configuration

0 = low brightness

1 = high brightness

Par.

Min.

Max.

Unit

Default

Main regulator

r0

1

15

°C/°F (1)

2

parameters differential r7, r8, r9, r10, r11 and r12

r1

1

500

min

90

duration of time-controlled blast chilling

r2

1

500

min

240

duration of time-controlled deep freezing

r3

-99

99

°C/°F (1)

3

temperature-controlled blast chilling end time temperature;

also end temperature of the temperature-controlled soft

deep freezing phase (temperature detected by the needle

probe); see also parameter r5

r4

-99

99

°C/°F (1)

-18

temperature-controlled deep freezing end temperature

(temperature detected by the needle probe); see also

parameter r6

r5

1

500

min

90

maximum duration of temperature-controlled blast chilling;

see parameter r3 also

r6

1

500

min

240

maximum

duration

of

temperature-controlled

deep

freezing; see parameter r4 also

r7

-99

99

°C/°F (1)

0

work set-point during blast chilling; also work set-point

during the soft deep freezing phase (cabinet temperature);

see also parameter r0

r8

-99

99

°C/°F (1)

-40

work set-point during deep freezing (cabinet temperature);

see also parameter r0

r9

-99

99

°C/°F (1)

-20

work set-point during hard blast chilling phase (cabinet

temperature); see also parameter r0

r10

-99

99

°C/°F (1)

2

work set-point during post blast chilling storage (cabinet

temperature); see also parameter r0

r11

-99

99

°C/°F (1)

-20

work set-point during post deep freezing storage (cabinet

temperature); see also parameter r0