EVCO EVCSR818P9EF User Manual
Page 73
EVCO S.p.A.
Vcolor 818
| Installer manual ver. 1.1 | Code 144VC818E114
page 73 of 94
u6
1
240
min
5
switching on UV light for sterilisation cycle duration
u7
-99
199
°C/°F (1)
40
needle probe heating end temperature (temperature
detected by the needle probe); see also parameter u8
u8
0
240
min
2
maximum duration of needle probe heating; see also
parameter u7
0 = needle probe heating is disabled
u9
0
1
- - - -
1
needle probe heating on opening of the door, i.e. on
activation of the door entry micro switch, which occurs after
interruption of a blast chilling and storage cycle or a deep
freezing and storage cycle during storage.
1 = yes
u11
0
1
- - - -
0
utility managed by the output K7 (15)
0 = cabinet light (in this case, the DEEP FREEZING key
and parameters i0 will assume significance)
1 = UV light (in this case, the DEEP FREEZING key and
parameter u6 will assume significance)
u12
0
999
s
10
compressor switch off delay from pump down valve
deactivation (pump down in switch-off) (16)
Par.
Min.
Max.
Unit
Default
Serial
communication
(RS-48
serial
port
with
MODBUS communication protocol)
L0
0
1
- - - -
0
operating mode
0 = slave (in this case, it will be possible to connect
Parameters Manager set-up software system, to the
monitoring and surveillance system of the RICS
plants or to the data recording device, to download
the
recorded
data
to
the
port
(via
USB)
EVUSBREC01).
1 = master (in this case, it will be possible to connect the
print module PM 100A X9S001 to the port)
L1
1
240
min
5
print interval during blast chilling or during deep freezing
L2
1
240
min
15
print interval during storage
LA
1
247
- - - -
247
device address