EVCO EVCSR818P9EF User Manual
Page 65

EVCO S.p.A.
Vcolor 818
| Installer manual ver. 1.1 | Code 144VC818E114
page 65 of 94
r12
-99
99
°C/°F (1)
5
work set-point during pre-cooling (cabinet temperature);
see also parameter r0
r13
-99
99
°C/°F (1)
15
end temperature of the temperature-controlled hard blast
chilling phase (temperature detected by the needle probe)
r14
10
100
%
60
duration of the time-controlled hard blast chilling phase
(intended as a percentage of the value established with
parameter r1); also duration of the time-controlled soft
deep freezing phase (intended as a percentage of the value
established with parameter r2)
r15
-99
199
°C/°F (1)
65
temperature below which the count of the maximum
temperature-controlled
blast
chilling
and
maximum
temperature-controlled
deep
freezing
is
started
(temperature detected by the needle probe)
r16
0
2
- - - -
1
type of operating cycle that can be selected
0 = blast chilling and storage
1 = blast chilling and storage or deep freezing and
storage
2 = deep freezing and storage
r17
0
99
°C/°F (1)
5
"temperature detected by the needle probe - cabinet
temperature" minimum difference such to consider the first
phase of the test to verify correct insertion of the needle
probe completed successfully (consider the difference
without sign)
0 = the test will not be performed (neither first or second
phase)
r18
1
99
10 s
20
duration of the second phase of the test for verification of
correct insertion of the needle probe
r19
- - - -
- - - -
- - - -
- - - -
reserved
r20
- - - -
- - - -
- - - -
- - - -
reserved
r22
- - - -
- - - -
- - - -
- - - -
reserved
r23
- - - -
- - - -
- - - -
- - - -
reserved
r40
- - - -
- - - -
- - - -
- - - -
reserved
r41
- - - -
- - - -
- - - -
- - - -
reserved
r42
- - - -
- - - -
- - - -
- - - -
reserved