5user interface, 1 foreword, 2 device commissioning – EVCO EVCSR818P9EF User Manual
Page 15

EVCO S.p.A.
Vcolor 818
| Installer manual ver. 1.1 | Code 144VC818E114
page 15 of 94
5
USER INTERFACE
5.1
Foreword
The following operating status exist:
-
the “off” status (the device is not powered)
-
the “stand-by” status (the device is powered and is off)
-
the “on” status (the device is powered, is on and is in stand-by for the start-up of an operating cycle)
-
the “run” status (the device is powered, is on and an operating cycle is in progress).
Hereon, the term "device switch-on" means the passage from the "stand-by" status to the "on" status. the term
"switch-off" means passage from the "on" status to the "stand-by" status.
If a power cut occurs during the "stand-by" status or during the "on" status, the device will re-propose the same
status when the power supply is restored.
If a power cut occurs during the "run" status, the device will operate as follows when this is restored:
-
if a temperature-controlled blast chilling or deep freezing operation was in progress, these will be started again
from the beginning
-
if a timed-controlled blast chilling or deep freezing operation was in progress, these will be started again from
the moment the power supply was cut-off
-
if storage was in progress, this will be re-proposed.
5.2
Device commissioning
Operate as follows:
1.
Connect the device power supply. if parameter E9 is set at 1, the device will display the EVCO splash screen for
10 s;
2.
After which it will go to the “stand-by” status.