beautypg.com

4 time-controlled blast chilling and storage – EVCO EVCSR818P9EF User Manual

Page 26

background image

EVCO S.p.A.

Vcolor 818

| Installer manual ver. 1.1 | Code 144VC818E114

page 26 of 94

Parameter r10 establishes the work set-point during storage.

If the temperature detected by the needle probe does not reach the blast chilling end temperature within the

maximum blast chilling duration, blast chilling will not be completed successfully but will continue and the buzzer will

be activated.

Press and release a key to restore normal display and to silence the buzzer.

When the temperature detected by the needle probe reaches the blast chilling end temperature, the device

automatically passes to storage in the same way as illustrated previously.

6.4

Time-controlled blast chilling and storage

The time-controlled blast chilling and storage cycle is divided into the following two phases:

-

blast chilling

-

storage.

On conclusion of a phase, the device passes automatically to the next.

Operate as indicated to start the cycle:

1.

Make sure the device is in the "on" status.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Press and release the key (1) and then press and release the key (2): the device will display the blast chilling

duration and the work set-point during blast chilling.