18 data print-out – EVCO EVCSR818P9EF User Manual
Page 50

EVCO S.p.A.
Vcolor 818
| Installer manual ver. 1.1 | Code 144VC818E114
page 50 of 94
6.18
Data print-out
The device can manage the PM 100A X9S001 module (to be ordered separately); see paragraph 14.5 "Print module PM
100A X9S001”.
Using the module, it is possible to print information relative to the cabinet temperature, the temperature detected by
the needle probe, at the alarms and at the errors (the latter two on condition that the alarm and/or the error is in
progress on expiry of the print interval.
Parameter L0 must be set at 1.
Parameter L1 establishes the print interval during blast chilling and during deep freezing and parameter L2 establishes
the print interval during storage.
The module prints the data as indicated:
************************
EVCO
************************
11/11/2011
CHILL TEMP
START
14:31
T
Tc
14:36
14 °C
39 °C
14:41
9 °C
25 °C
14:46
2 °C
12 °C
14:51
-1 °C
7 °C
14:56
0 °C
4 °C
==>
14:58
15:13
1 °C
15:28
3 °C
15:43
2 °C
STOP
15:32
Key:
T
cabinet temperature
Tc
temperature detected by the needle probe
==> passage to storage.