beautypg.com

11 continuous deep freezing – EVCO EVCSR818P9EF User Manual

Page 40

background image

EVCO S.p.A.

Vcolor 818

| Installer manual ver. 1.1 | Code 144VC818E114

page 40 of 94

Parameter r11 establishes the work set-point during storage.

6.11

Continuous deep freezing

Operate as indicated to start the cycle:

1.

Make sure the device is in the "on" status.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Press and release the key (1), press and release the key (2) and then press and release the key (3) twice. The

device will display the work set-point during deep freezing.

4.1

Press and release the MENU key and then press and release the key (4) or the key (5) to select the work set-

point during deep freezing.

4.2

Press and release the key + (6) or the key – (7) to modify this value and then the ESCAPE key to memorise it;

this value can also be memorised through parameter r8.