Lb
0
3
- - - -
2
baud rate
0 = 2,400 baud
1 = 4,800 baud
2 = 9,600 baud
3 = 19,200 baud
LP
0
2
- - - -
2
parity
0 = none (no parity)
1 = odd
2 = even
Par.
Min.
Max.
Unit
Default
Various
E8
0
2
- - - -
0
"keyboard lock" function activation mode
0 = function not enabled
1 = manual with permanent effect (to lock the keyboard,
make sure no procedure is in progress, after which
press and release the ON/STAND-BY key and then
press the highest interactive key on the left; to
unlock the keyboard repeat the procedure)
2 = automatic with temporary effect (on expiry of 60 s
the keybord will automatically lock; to unlock the
keyboard, make sure no procedure is in progress,
after which press and release the ON/STAND-BY key
and then press the highest interactive key on the
left)
E9
0
1
- - - -
1
EVCO splash screen display during passage from the "off"
status to the "stand-by" status and restore of the power
supply.
1 = yes
Notes:
(1)
the unit of measurement depends on parameter P2
(2)
appropriately set the parameters relative to the regulators after modification of parameter P2
(3)
the time established with the parameter is counted also during the "on" status and during the "stand-by" status
(4)
The parameter differential is 2 °C/4 °F
(5)
on device switch-on (or cycle start), if the condenser temperature is already over that established with
parameter C7, parameter C8 will have no effect
(6)
defrosting is only enabled during pre-cooling, on start-up of blast chilling and at the start-up of deep freezing
(in these last two cases on condition that parameter d4 is set at 1) and during storage
(7)
the device memorises the defrosting interval count every 30 minutes; the modification of parameter d0 has
effect from the conclusion of the previous defrosting interval (or the activation of defrosting in manual mode)