TOSHIBA
6 F 8 A 0 7 7 0
To change the fixed pulse output value:
The following example show-s how to change the fixed puliie oulput value from 50 pps to
100 pps.
K e y
operation
Display example
Description
SET
□
L3; FIX. PULSE
050 PPS
Press [SET] first to start the items selection sequence
md select L3: FIX, PULSE from among the
configuration items using [ ► ] and [
a
j keys. Then
press [SUT| again to display the current fixed pulse
output value (50 pps in this example).
►
L3: FIX. PULSE
050 PPS
Pressing [ ► ], the cursor appears.
necessary, move the cursor by pressing [ ► ] to the
digit to be changed,)
▲
L3t FIX. PULSE
150 PPS
100 PPS
Change the value to ’ by pressing [
a
. j. 'fhen move
:he cursor to another digit to change and change the
value. In this example repeat this process until the
display shows “lOOpps,”
SET
L3: FIX. PULSE
IGO PPS
Pressing [SET], the cursor disappears and the changed
value display flickers. Press [SET] again lo save the
value.
SFT
□
L3: FIX. PULSE
Pressing [SET], the system returns to the items
selection sequence.
i'ixed current output value can be chiuiged by selecting the configuration item L2: FIX,
CURR,
-