6 F . 8 A 0 7 7 0 ,
Preset pciint output perforin£ince(2)
The following is an example for preset point output (pulse out mode ) in which the totalizer
is reset with un
cxtcmEi!
signal (Dl diitcctive level
is
L).
Note; Only In case of the converter for special specifications (refer to 7.3,3 "‘Converter for
Special specifications’*), this preset point output (one shot pulse mode) can be selected.
II level inout
L level input
Preset point
ON
OFF
When the li.esetÀStart signal is in L level, the totalizer is reset to zero and stops counting.
When the Reset/Start signal goes to H level, the totalizer starts counting.
The preset point outptn goes ON when the totalizer cotints reaches the preset point.
I’he output goes OFF when the totalizer is reset to zero or when it takes the time setted
pulse width from the output goes ON,
-
125
“