5 normal mode commands, Normal mode commands – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual
Page 81

EDP Commands
75
6.1.5
Normal Mode Commands
The normal mode commands (see Table 6-20) transmit data to the EDP port on demand. The SX, EX, and all the
"X" weight retrieval commands are valid only in normal operating mode; all other commands are valid in either
setup or normal mode.
Table 6-20. Normal Mode EDP Commands
Command
Function
CONSNUM
Set or query the consecutive number
UID
Set or query the unit ID
SD
Set or query the date. Enter six-digit date using the year-month-day order specified for the DATEFMT
parameter, using only the last two digits of the year.
ST
Set or query the time. Enter the time using 24-hour format
SX#n
Start serial port streaming. If port is configured to stream on port #1 - 4. (1=COM, 2=USBCOM, 3=Ethernet
Server, 4=Ethernet Client)
SX
Start serial port streaming for the port receiving the command, if port is configured to stream.
EX#n
Stop serial port streaming. If port is configured to stream on port #1 - 4. (1=COM, 2=USBCOM, 3=Ethernet
Server, 4=Ethernet Client)
EX
Stop serial port streaming for the port receiving the command, if port is configured to stream.
RS
Reset system. This is a soft reset. Used to reset the indicator without resetting the configuration to the
factory defaults.
S
Sends a single stream frame from the scale to the port in the format defined by the Stream Format parameter
of the port receiving the command.
XA#n
Transmit accumulator value in displayed units for scale n
XA
Transmit accumulator value in displayed units for selected scale
XAP#n
Transmit accumulator value in primary units for scale n
XAS#n
Transmit accumulator value in secondary units for scale n
XG#n
Transmit gross weight in displayed units for scale n
XG
Transmit gross weight in displayed units for selected scale
XG2
Transmit gross weight in non-displayed units for selected scale
XGP#n
Transmit gross weight in primary units for scale n
XGS#n
Transmit gross weight in secondary units for scale n
XN#n
Transmit net weight in displayed units for scale n
XN
Transmit net weight in displayed units for selected scale
XN2
Transmit net weight in non-displayed units for selected scale
XNP#n
Transmit net weight in primary units for scale n
XNS#n
Transmit net weight in secondary units for scale n
XT#n
Transmit tare weight in displayed units for scale n
XT
Transmit tare weight in displayed units for selected scale
XT2
Transmit tare weight in non-displayed units for selected scale
XTP#n
Transmit tare weight in primary units for scale n
XTS#n
Transmit tare weight in secondary units for scale n
XE
Returns a decimal representation of any error conditions
XEH
Returns a hexadecimal representation of any error conditions
Note
The 880 only supports one scale.