Sted in table 6-16 ca, Setpoints menu – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual
Page 78

72
880 Technical/Service Manual
Setpoints Menu
Note
Table 6-16. Setpoints EDP Commands
Command
Menu
Description
Choices / Range
SP.ACCESS#n
ACCESS
Setpoint access in top level menu (user)
OFF, ON
SP.BANDVAL#n
BNDVAL
Band value
0 - 999999
SP.BRANCH#n
BRANCH
Branch destination
0,1-20
SP.CLRACCM#n
CLRACM
Clear accumulator
OFF, ON
SP.CLRTAR#n
CLRTAR
Clear tare
OFF, ON
SP.DIGOUT#n
DIGOUT
Lists all digital output bits available for the
specified SLOT
NONE, BIT1 – BIT4
SP.END#n
END
Ending setpoint number for TIMER and CONCUR
1- 20
SP.HYSTER#n
HYSTER
Hysteresis
Range:
0 - 65535 (for the COUNTR and
DELAY setpoints)
0 - 999999 (for the GROSS,
NET, and %REL setpoints)
SP.KIND#n
Selection made
directly after
dropping down
from SETPT x
Supported setpoint kinds
OFF, GROSS, NET, -GROSS,
-NET, %REL, PAUSE, DELAY,
WAITSS, COUNTR, AUTJOG,
TIMER, CONCUR
SP.BATSEQ#n
BATSEQ
Specifies whether the setpoint is a batch step
OFF, ON
SP.NAME#n
NAME
Setpoint name string
Alphanumeric, Max Length: 6
SP.PCOUNT#n
PCOUNT
Preact learn interval (number of cycles before it
learns)
Range: 0 - 65535
SP.PREACT#n
PREACT
Preact type
OFF, ON, LEARN
SP.PREADJ#n
PREADJ
Preact adjustment percentage
Range: 0 – 999999
SP.PRESTAB#n
PRESTB
Preact learn stability
Range: 0 - 65535
SP.PREVAL#n
PREVAL
Preact value
Range: 0 - 999999
SP.PSHACCM#n
PSHACM
Push accumulate
OFF, ON, ONQUIET
SP.PSHPRINT#n
PSHPRT
Push print
OFF, ON, WAITSS
SP.PSHTARE#n
PSHTAR
Push tare
OFF, ON
SP.RELNUM#n
RELNUM
Relative setpoint number
1- 20
SP.SENSE#n
SENSE
Digital output sense
NORMAL, INVERT
SP.DSLOT#n
SLOT
Digital output slot
NONE, SLOT0, SLOT1
SP.START#n
START
Starting setpoint number for TIMER and CONCUR 1- 20
SP.TRIP#n
TRIP
Specifies when the setpoint is satisfied when
compared to value
HIGHER, LOWER, INBAND,
OUTBAND
SP.VALUE#n
VALUE
Setpoint value
Range:
0 - 65535 (for the COUNTR
and DELAY setpoints)
0 - 999999 (for the GROSS,
NET, and %REL setpoints)
BATCHNG
BATCHG
Batching enable
OFF, AUTO, MANUAL
Note
For setpoint commands the “n” symbolizes the setpoint number, 1-20.
Different setpoint parameters are available and accepted depending on KIND, TRIP, and PREACT. These
restrictions are listed below by the EDP command name but the same applies to access by menu.