6.1.2
Reporting Commands
Reporting commands (see Table 6-2) send specific information to the EDP port. These commands can be used in
both setup mode and normal mode.
Table 6-2. EDP Reporting Commands
Command
Function
AUDITJUMPER
Returns the state of the audit jumper. A response of OK indicates the jumper is in the ON position.
A response of “??” indicates the jumper is in the OFF position.
BUILD
Returns the date and time of the software build.
DUMPALL
Returns a list of all parameter values
DUMPAUDIT
Returns a list of audit trail information
DUMPCONFIG
Returns a list of all parameter values except for setpoint data
DUMPETH
Returns a list of all Ethernet parameter values
DUMPSP
Returns a list of all setpoint parameter values
HARDWARE
Returns a value that indicates which option card is installed in the option slot
Possible values:
000=none, 085=relay card, 153=analog output card, 170=CompactCom card
Example response with a relay card installed:
HARDWARE=085
VERSION
Returns the 880 firmware version
DISPLAYBUILD
Returns the date and time of the display module software build. NONE is returned if no display if
connected.
DISPLAYVERSION
Returns the display module software version. NONE is returned if no display if connected
P
Returns the current displayed weight with units identifier, see Section 10.4
OPTVERSION
Returns the software version of an installed option card, if supported. Returns UNSUPPORTED if
not supported. Returns NOCARD if no option card is installed.
FBTEST
Returns the type of Field Bus module that is connected to the Field Bus Option Card, if installed.
Returns NO MODULE if no module is installed. Returns NOT FOUND if no Field Bus Option Card is
installed.
6.1.3
The RESETCONFIGURATION Command
The RESETCONFIGURATION command can be used in setup mode to restore all configuration parameters to
their default values.
This command is equivalent to using the DEFALT function in CONFIG mode.
Note
All load cell calibration settings are lost when the RESETCONFIGURATION command is run.
6.1.4
Parameter Setting Commands
Parameter setting commands allow the display or change of the current value for a particular configuration
parameter (Tables 6-3 through 6-22).
Current configuration parameter settings can be displayed in either setup mode or normal mode using the following
syntax:
command
Most parameter values can be changed in setup mode only; setpoint parameters listed in Table 6-16 can be changed
when in normal weighing mode.
Use the following command syntax when changing parameter values:
command=value
where
value
is either a number or a parameter value. Use no spaces before or after the equal (=) sign. If an incorrect
command has been typed in, the response will be
??
.
For example, to set the motion band parameter to 5, type the following:
SC.MOTBAND#1=5D
For parameters with selectable values, enter the command and equal sign followed by a question mark:
command=?
to see a list of those values. The indicator must be in setup mode to use this function.