6 preset tare (keyed tare), 7 print ticket, 8 front panel setup – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual
Page 12: 9 displaying audit trail information, Preset tare (keyed tare), Print ticket, Front panel setup, Displaying audit trail information, See section 1.4.8

6
880 Technical/Service Manual
1.4.6
Preset Tare (Keyed Tare)
Note
Tare mode must be set to keyed or both for the preset tare feature to function.
1. With the scale empty and display showing zero weight, press
TARE
.
2. Display will show (000000); the focused digit will flash.
3. To edit the value:
• Press or to select the digit.
• Press or to increment or decrement the value.
• Press
TARE
to move to the decimal point entry.
• Press or to adjust the decimal point placement.
• Press
TARE
when the value is correct.
4. The display will change to the Net mode and the
PT
LED lights to show the preset tare was entered.
Note
Entering a keyed tare of zero will remove the stored tare value.
1.4.7
Print Ticket
1. Wait for the (
) LED to light.
2. Press
to send data to a communications port.
1.4.8
Front Panel Setup
1. Press
MENU
to enter user setup mode. Use user setup to:
• View audit trail information
• Enter setup mode if audit trail is enabled
• View or set time and date
• View or clear the accumulator
• Change setpoint values and enable/disable setpoints
• View the current tare value
1.4.9
Displaying Audit Trail Information
The Audit Trail Configuration and Calibration counters can be viewed through the User Menu.
1. Press
MENU
, AUDIT is displayed.
2. Press to display the Legally Relevant Firmware version.
3. Press to display CALIB.
4. Press to view the Calibration Counter.
5. Press
MENU
to return to CALIB.
6. Press to display CFG.
7. Press to view the Configuration Counter.
8. Press
MENU
to return to CFG.
9. Press
MENU
to return to the weigh mode.