Metrohm 785 DMP Titrino User Manual

Page 94

background image

3.2 Remote control commands

785 DMP Titrino

91

³ ³ Ã

.C43

Volume drift in SET

read only/read+write

³ ³ Ã

.C44

Titration temperature

read only/read+write

³ ³ Ã

.C45

Start volume

read only/read+write

³ ³ Ã

.C46

Asymmetry pH

read only

³ ³ Ã

.C47

Slope of electrode

read only

³ ³ Ã

.C48

Volume at maximum voltage

read only/read+write

³ ³ Ã

.C49

Volume at minimum voltage

read only/read+write

³ ³ Ã

.DTime

Time for drift corr.or dosing time

read only/read+write

³ Ã

.FixEP

Fix EP

³ ³ Ã

.51

C51

³ ³ ³ Ã

.Value

Value

read only

3.2.2.97.

³ ³ ³

up to 59

³ Ã

.pK

pK/HNP

³ ³ Ã

.61

C61

³ ³ ³ Ã

.Value

Value

read only

ditto

³ ³ ³

up to 69

³ Ã

.TempVar

Temporary variables C7X

³ ³ Ã

.C70

up to C79

read only/read+write

ditto

³

Ã

.StatisticsVal

Statistics values

³ Ã

.ActN

Number of results in chart

read only

3.2.2.98.

³ Ã

.1

1

st

mean

³ ³ Ã

.Mean

Mean

read only

ditto

³ ³ Ã

.Std

Absolute standard deviation

read only

ditto

³ ³ Ã

.RelStd

Relative standard deviation

read only

ditto

³ Ã

up to 9 mean values

³

Ã

.SiloCalc

Values of silo calculations

³ Ã

.C24

Values of variable C24

³ ³ Ã

.Name

Name

read only

3.2.2.99.

³ ³ Ã

.Value

Value

read only

ditto

³ ³ Ã

.Unit

Unit

read only

ditto

³ Ã

.C25

as for C24

³ Ã

.C26

Values of variable C26

³ ³ Ã

.ActN

Number of single values

read only

ditto

³ ³ Ã

.Mean

Mean value

read only

ditto

³ ³ Ã

.Std

Absolute standard deviation

read only

ditto

³ ³ Ã

.RelStd

Relative standard deviation

read only

ditto

³ Ã

.C27

as for C26

³

"Info", continuation

Ã

.ActualInfo

Current data

³ Ã

.Inputs

I/O Inputs

³ ³ Ã

.Status

Line status

read only

3.2.2.100.

³ ³ Ã

.Change

Change of line status

read only

ditto

³ ³ Ã

.Clear

Clear change

$G

ditto

³ Ã

.Outputs

as for I/O Inputs

³ Ã

.Assembly

From Assembly

³ ³ Ã

.CyclNo

Cycle number

read only

3.2.2.101.

³ ³ Ã

.Counter

Assembly counter

read only

3.2.2.102.

³ ³ ³ Ã

.V

Volume counter

read only

ditto

³ ³ ³ Ã

.Clear

Clears counter

$G

ditto

³ ³ Ã

.Meas

Measured value

read only

3.2.2.103.

³ Ã

.Titrator

From Titrator

³ ³ Ã

.CyclNo

Cycle number

read only

3.2.2.104.

³ ³ Ã

.V

Volume

read only

ditto

³ ³ Ã

.Meas

Measured indicator voltage

read only

ditto

³ ³ Ã

.dVdt

Volume drift dV/dt

read only

ditto

³ ³ Ã

.dMeasdt

Measured value drift

read only

ditto