Metrohm 785 DMP Titrino User Manual
Page 82
3.2 Remote control commands
785 DMP Titrino
79
*Parameter
Tree part "Parameters for DET"
Ã
.
TitrPara
Titration parameters
³ Ã
.MptDensity
Measuring point density
0...4...9
3.2.2.12.
³ Ã
.MinIncr
Minimum increment
0...10.0...999.9
ditto
³ Ã
.DosRate
Dispensing rate for increments
0.01...150.0, max.
3.2.2.13.
³ Ã
.SignalDrift
Drift for meas. value acquisition
depends on meas.quant. 3.2.2.14.
³ Ã
.UnitSigDrift
Unit of measured value drift
read only
ditto
³ Ã
.EquTime
Equilibrium time
0...26...9999, OFF
ditto
³ Ã
.StartV
Start volume
³ ³ Ã
.Type
Type of start volume
abs., rel., OFF
3.2.2.15.
³ ³ Ã
.V
Volume for absolute start volume
0...999.99
ditto
³ ³ Ã
.Factor
Factor for relative start volume
0...
±
999 999
ditto
³ ³ Ã
.Rate
Dispensing rate for start volume
0.01...150.0, max.
ditto
³ Ã
.Pause
Waiting time
0...999 999
3.2.2.16.
³ Ã
.MeasInput
Measuring input
1, 2, diff.
3.2.2.17.
³ Ã
.Ipol
Polarization current
0...1...
±
127
ditto
³ Ã
.Upol
Polarization voltage
0...400...
±
1270
ditto
³ Ã
.PolElectrTest
Test for polarized electrodes
ON, OFF
ditto
³ Ã
.Temp
Titration temperature
-170.0...25.0...500.0
3.2.2.18.
³
Ã
.
StopCond
Stop conditions
³ Ã
.VStop
Stop volume
³ ³ Ã
.Type
Type of stop volume
abs., rel., OFF
3.2.2.19.
³ ³ Ã
.V
Volume for absolute stop volume
0...99.99...9999.99
ditto
³ ³ Ã
.Factor
Factor for relative stop volume
0...
±
999 999
ditto
³ Ã
.MeasStop
Stop measured value pH, U, I
depends on meas.quant. 3.2.2.20.
³ Ã
.UnitMStop
Unit of stop measured value
read only
ditto
³ Ã
.EPStop
Stop after a number of EP's
1...9, OFF
3.2.2.21.
³ Ã
.FillRate
Filling rate
0.01...150.0, max.
3.2.2.22.
³
Ã
.
Statistics
Statistics
³ Ã
.Status
Status of statistics calculation
ON, OFF
3.2.2.23.
³ Ã
.MeanN
No. of individual determinations
2...20
ditto
³ Ã
.ResTab
Result table
³ ³ Ã
.Select
original,delete n,delete all
ditto
³ ³ Ã
.DelN
Deletion of individual results
1...20
ditto
³
Ã
.
Evaluation
Evaluation
³ Ã
.EPC
EP criterion
0...5...200
3.2.2.24.
³ Ã
.Recognition
EP recognition
³ ³ Ã
.Select
Type of EP recognition
all,greatest,last,window,OFF ditto
³ ³ Ã
.Window
Window
³ ³ ³ Ã
.1
up to 9 windows
³ ³ ³ ³ Ã
.LowLim
Lower limit window 1
depends on meas.quant.
ditto
³ ³ ³ ³ Ã
.UpLim
Upper limit window 1
depends on meas.quant.
ditto
³ Ã
.FixEP
Fix endpoints
³ ³ Ã
.1
up to 9 fix EP's
³ ³ ³ Ã
.Value
Measured value for fix EP1
depends on meas.quant.
ditto
³ Ã
.pK
pK or HNP evaluation
ON, OFF
ditto
³
Ã
.
Presel
Preselections
³ Ã
.IReq
Request of Id's after start
id1, id1&2, all, OFF
3.2.2.25.
³ Ã
.Sreq
Request of smpl size after start
value, unit, all, OFF
ditto
³ Ã
.LimSmplSize
Limits for sample size
3.2.2.26.
³ ³ Ã
.Status
Status of limit control
ON, OFF
ditto
³ ³ Ã
.LoLim
Lower limit
0.0...999 999
ditto
³ ³ Ã
.UpLim
Upper limit
0.0...999 999
ditto
³ Ã
.ActPulse
Output of a pulse
ON, OFF
3.2.2.27.