Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual
Page 86

86
Rockwell Automation Publication D2-3518-3 - May 2013
Chapter 9
Value of volts dropped across the resistance of the motor stator. Used only when
Torque Perf Mode (53) is set to Sensrls Vect or SV Economize.
When inverter Autotune (61) is set to Calculate, the value of this parameter is
set according to the motor nameplate parameters, and you cannot write to this
parameter.
Value of RMS motor amps for full motor flux. Used only when Torque Perf
Mode (53) is set to Sensrls Vect or SV Economize.
When inverter Autotune (61) is set to Calculate, the value of this parameter is
set according to the motor nameplate parameters, and you cannot write to this
parameter.
This parameter should be left at its default value of 0.0V AC.
Sets the voltage boost level for starting and acceleration when Custom V/Hz
mode is selected in Torque Perf Mode (53).
62
IR Voltage Drop
Range:
0.0 to Motor NP Volts x 0.25 [0.1V AC]
Default:
Based on Drive Rating
Access:
1
Path: Motor Control > Torq Attributes
See also:
53
63
Flux Current Ref
Range:
0.00 to Drive Rated Amps [0.01 A]
Default:
Based on Drive Rating
Access:
1
Path: Motor Control > Torq Attributes
See also:
53
64
Ixo Voltage Drop
Range:
0.00...20.0V [0.1V AC]
Default:
0.0V AC
Access:
1
Path: Motor Control > Torq Attributes
See also:
69
Start/Acc Boost
Range:
0.0 to Motor NP Volts x 0.25 [0.1V AC]
Default:
Based on drive rating
Access:
1
Path: Motor Control > Volts per Hertz
See also:
53, 70, 83
32