238 fault config 1, 240 fault clear, 241 fault clear mode – Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual

Page 129: 242 power up marker

background image

Rockwell Automation Publication D2-3518-3 - May 2013

129

Chapter 9

Enables/disables annunciation of the faults shown in

Figure 57

.

Figure 57 - Fault Config 1 (238)

Resets a fault and clears the fault queue. After the fault clear operation is
complete, this parameter returns to the value of 0 for Ready.

Enables/disables a fault reset (clear faults) attempt from any source.

Accumulated hours that inverter had been powered up at the time of the most
recent drive powerup.

238

Fault Config 1

Range:

See

Figure 57

Default:

See

Figure 57

Access:

0

Path: Utility > Faults

See also:

240

Fault Clear

Range:

0 = Ready
1 = Clear Faults
2 = Clr Flt Que

Default:

0 = Ready

Access:

1

Path: Utility > Faults

See also:

241

Fault Clear Mode

Range:

0 = Disabled
1 = Enabled

Default:

1 = Enabled

Access:

1

Path: Utility > Faults

See also:

242

Power Up Marker

Range:

0.0000...4,294,967.2925 Hr [0.0001 Hr]

Default:

Read Only

Access:

1

Path: Utility > Faults

See also:

244, 246, 248, 250, 252, 254, 256, 258

1

x

1

1

0

0

0

x

x

x

x

x

x

x

x

x

0

0

1

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Enabled
0 =Disabled
x =Reserved

Bit #

Factory Default Bit Values

Po

w

er Loss

Und

erV

oltage

Motor Ov

erLd

Shear Pin

Au

tRst T

ries

Decel

Inhibit

Nibble 1

Nibble 2

Nibble 3

Nibble 4