Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual
Page 124
124
Rockwell Automation Publication D2-3518-3 - May 2013
Chapter 9
This parameter contains the current state of digital outputs controlled by the
inverter. See
AC Line I/O Board Description (Frame 3 Only) on page 25
through
Combined I/O Board Description (Frame 4 Only) on page 29
for a
description of I/O hardware that is present on this drive and is controlled by the
inverter.
Frame 3 drives (firmware version 1.x) only:
Current state of the user-configurable digital outputs. These outputs are located
on the optional Standard I/O board, which is not present in all drives.
Figure 51 - Dig Out Status (276) Frame 3
Frame 4 drives (firmware version 2.x) only:
Current state of the inverter-controlled digital outputs.
Digital outputs 1 and 2 are the user-configurable digital outputs. Digital Outputs
3...8 are the application controlled digital outputs. All of these digital outputs are
located on the Combined I/O board.
Figure 52 - Dig Out Status (276) Frame 4
217
Dig Out Status
Range:
See
and
Default:
Read Only
Access:
0
Path: Utility > Diagnostics
See also:
30, 380...384
0
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
0
0
1
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Output Energized
0 =Output De-energized
x =Reserved
Bit #
Digital Out1
Digital Out2
Nibble 1
Nibble 2
Nibble 3
Nibble 4
0
x
x
x
x
x
0
0
1
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Condition True
0 =Condition False
x =Reserved
Bit #
Digital Output 1
Nibble 1
Nibble 2
Nibble 3
Nibble 4
x
x
x
0
0
0 0
0
0
0
Digital Output 6
Digital Output 8
Digital Output 2
Digital Output 7
Digital Output 5
Digital Output 4
Digital Output 3