beautypg.com

Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual

Page 275

background image

Rockwell Automation Publication 1783-UM004E-EN-P - June 2014

275

Cables and Connectors Appendix C

Figure 13 - Two Twisted-pair Straight-through Cable Schematic

Figure 14 - Four Twisted-pair Straight-through Cable Schematic

When connecting the ports to 10BASE-T- and 100BASE-TX-compatible
devices, such as switches or repeaters, you can use a two or four twisted-pair,
crossover cable.

The following figures show these schematics:

Two twisted-pair, crossover cable schematics
Four twisted-pair, crossover cable schematics

Use a straight-through cable to connect two ports when only one port is
designated with an X. Use a crossover cable to connect two ports when both
ports are designated with an X or when both ports do not have an X.

You can use Category 3, 4, or 5 cabling when connecting to 10BASE-T-
compatible devices. You must use Category 5 cabling when connecting to
100BASE-TX-compatible devices.

IMPORTANT

Use a four twisted-pair, Category 5 cable when connecting to a 1000BASE-T-
compatible device or PoE port.

Switch

3 TD+
6 TD–

1 RD+

2 RD–

Router or Personal Computer

3 RD+
6 RD–

1 TD+
2 TD–

1 TPO+

2 TPO-

3 TP1+

6 TP1-

1 TP1+

Switch

Router or Personal Computer

2 TP1-

3 TPO+

6 TPO-

4 TP2+

5 TP2-

7 TP3+

8 TP3-

4 TP3+

5 TP3-

7 TP2+

8 TP2-