218

Rockwell Automation Publication 1783-UM004E-EN-P - June 2014

Chapter 5 Manage the Switch via the Studio 5000 Environment

5. Do one of the following:

To translate a single address for a device on the private subnet that

needs to communicate on the public subnet, complete the fields below.

To translate a range of addresses for devices on the private subnet that

need to communicate on the public subnet, complete the fields below.

Field

Description

Type of Entry

Choose Single. This is the default value.

Starting Private IP Address Type the existing address for the device on the private subnet.

Starting Public IP Address

Type a unique public address to represent the device.

Effective Private Addresses

Displays the existing address for the device on the private subnet that is
configured for translation.
If blank, verify that the values in the fields above are valid.

Effective Public Addresses

Displays the unique public address to represent the device.
If blank, verify that the values in the fields above are valid.

Field

Description

Type of Entry

Choose Range.

Starting Private IP Address

Type the existing starting address for the device on the private subnet.

Starting Public IP Address

Type a unique, starting public address to represent the device.

Range

Type the number of addresses to include in the range.
Valid values: 1…128

Default value = 1
IMPORTANT: Each address in the range counts as one translation entry.

The switch supports a maximum of 128 translation entries.

Effective Private Addresses

Displays the range of existing addresses for devices on the private subnet
that are configured for translation.
If blank, verify that the values in the fields above are valid.

Effective Public Addresses

Displays the range of unique public addresses to represent the devices.
If blank, verify that the values in the fields above are valid.