Module information – Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual
Page 196
![background image](/manuals/579905/196/background.png)
196
Rockwell Automation Publication 1783-UM004E-EN-P - June 2014
Chapter 5 Manage the Switch via the Studio 5000 Environment
Module Information
You can monitor and reset the switch from the Module Info tab.
Table 29 - Module Info Tab Fields
Field
Description
Identification
Displays the following information about the switch:
• Vendor
• Product type
• Product code
• Revision
• Serial number
• Product name
Status
Displays the status of the following:
• Major/minor fault status:
– None
– Recoverable
– Non-recoverable
• Configuration:
– Non-default configuration
– Default configuration
• Owned. Indicates whether there is an I/O connection:
– Yes
– No
• Module identity:
– Match. Agrees with what is specified on the General tab. In order for the Match condition to exist, the vendor, product type, product code,
and major revision must agree.
– Mismatch. Does not agree with what is specified on the General tab.
The Module Identify field does not take into account the Electronic Keying or Minor Revision selections for the switch that were specified on
the General tab.
Refresh
Click to refresh the tab with new data from the module.
Reset Module
Click to perform a switch reset (power cycle) with the current configuration file. The Password Confirmation dialog box can appear.
ATTENTION: Resetting a module causes all connections to or through the module to be closed. This can result in loss of control.