6 - troubleshoot the switch, Verify boot fast, Ip address issues – Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual
Page 235: Chapter 6, Troubleshoot the switch, Verify boot fast ip address issues, Chapter
Rockwell Automation Publication 1783-UM004E-EN-P - June 2014
235
Chapter
6
Troubleshoot the Switch
This chapter helps you resolve issues related to Stratix 5700 switches, as well as
perform common functions such as resetting the switch.
For additional troubleshooting, refer to the following:
•
Diagnose Cabling Problems on page 176
•
View System Log Messages on page 177
Verify Boot Fast
Boot fast failures are potentially fatal to the switch. Contact your Rockwell
Automation representative if your switch does not successfully complete boot
fast. You can disable the boot fast and run a power-on self test (POST) by using
the CLI.
IP Address Issues
These are some basic troubleshooting tips for issues related to the switch IP
address.
Topic
Page
Device Manager Web Interface Issues
Recover the Switch Firmware and Restore Factory Defaults
Troubleshoot a Firmware Upgrade
Issue
Resolution
IP address is not received from DHCP server
If the switch does not receive an IP address from an upstream device operating as a DHCP server, make sure that the
upstream device is operating as a DHCP server and again follow the procedures to set up the switch in
Chapter 1, About
Switch has wrong IP address
If the switch is installed in your network but you cannot access the switch because it has the wrong IP address, assign a
new switch IP address.
Refer to Access Direct Managed Mode on page 237
to assign the IP address, and then update the
switch IP address on the Device Manager Express Setup window.