Restart or reset the switch – Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual
Page 239
Rockwell Automation Publication 1783-UM004E-EN-P - June 2014
239
Troubleshoot the Switch Chapter 6
Restart or Reset the Switch
If you cannot solve an issue by reconfiguring a feature, either restarting or
resetting the switch can solve the issue or help you to eliminate probable causes. If
the issue exists after you reset the switch to its default settings, it is unlikely that
the switch is causing the issue.
Restart the Switch from the Device Manager Web Interface
From the Device Manager Web interface, on the Restart/Reset dialog box, click
Restart the Switch.
This option restarts the switch without turning off power. The Device Manager
Web interface is unavailable during the restart process. When the process
completes, the switch displays the Device Manager Web interface.
If you do not know the switch IP address, follow the procedure in the
Direct Managed Mode section on page 237
to access Direct Managed mode.
Restart the Switch from the Logix Designer Application
From Module Properties dialog box within the Logix Designer application, do
the following.
1. Click the Module Info tab.
2. Click Reset Module.
A password prompt appears.
3. Enter your password and click Enter.
Option
Description
Restart
This option restarts the switch without turning off power. The switch retains its saved configuration settings during the restart process. However, the
Device Manager Web interface is unavailable during the process. When the process completes, the switch displays the Device Manager Web
interface.
IMPORTANT: Restarting the switch interrupts connectivity of your devices to the network.
Reset the Switch to Factory
Defaults
This option resets the switch, deletes the current configuration settings, returns to the factory default settings, and then restarts the switch.
ATTENTION: Resetting the switch deletes all customized switch settings, including the IP address, and returns the switch to the factory default
settings. The same software image is retained. You need to reconfigure the basic switch settings.
Refer to ArmorStratix 5700 Switch Installation on
.
ATTENTION: Resetting the switch interrupts connectivity of your devices to the network.
IMPORTANT
Restarting or resetting the switch interrupts connectivity of your devices to the
network.