beautypg.com

Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual

Page 147

background image

Rockwell Automation Publication 1783-UM004E-EN-P - June 2014

147

Manage the Switch via the Device Manager Web Interface Chapter 4

Delay Request Interval

The time interval recommended to connected devices to send delay request messages when the switch port is in the

master state:
• -1 means half second
• 0 means 1 second
• 1 means 2 seconds
• 2 means 4 seconds
• 3 means 8 seconds
• 4 means 16 seconds
• 5 means 32 seconds
• 6 means 64 seconds

The default is 5 (32 seconds).

Announce Timeout

The number of announce intervals that must pass without receipt of an announce message from the Grandmaster clock

before the switch selects a new Grandmaster clock. The number can be from 2…10. The default is 3.

Announce Interval

The time interval for sending announce messages:

• 0 means 1 second
• 1 means 2 seconds
• 2 means 4 seconds
• 3 means 8 seconds
• 4 means 16 seconds

The default is 1 (2 seconds).

Sync Interval

The time interval for sending synchronization messages:

• -1 means half second
• 0 means 1 second
• 1 means 2 seconds

The default is 0 (1 second).

Sync Fault Limit

The maximum clock offset before PTP attempts to reacquire synchronization. The value can be from 50…500,000,000

nanoseconds. The default is 50,000 nanoseconds.

We recommend against setting the sync limit below the default (50,000 nanoseconds).

Use values below 50,000 nanoseconds only in networks with a very-high-precision Grandmaster clock. These networks
have a critical need to keep very sensitive devices synchronized.

Table 16 - PTP Fields (continued)

Field

Description