Troubleshoot a firmware upgrade – Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual
Page 241
Rockwell Automation Publication 1783-UM004E-EN-P - June 2014
241
Troubleshoot the Switch Chapter 6
3. Wait for the switch to restart.
The Express Setup indicator begins flashing when the switch has
completed restarting. The switch has now been returned to factory
defaults.
4. Set up the switch, as described in
ArmorStratix 5700 Switch Installation
5.
Refer to Troubleshoot a Firmware Upgrade on page 241
and follow the
procedure to upgrade the firmware.
Troubleshoot a
Firmware Upgrade
If you attempted to upgrade the switch firmware but received a message that the
upgrade failed, make sure that you still have access to the switch. If you still have
switch access, follow these steps.
1. Make sure that you downloaded the correct .tar file from
2. If you downloaded the correct .tar file, refresh your Device Manager Web
interface browser session to make sure that there is connectivity between
the switch and your computer or laptop or network drive.
• If you have connectivity to the switch and the Device Manager Web
interface, retry the upgrade.
• If you do not have connectivity to the switch and the Device Manager
Web interface,
refer to Recover the Switch Firmware and Restore
.