Acknowledge handler object — class code 0x002b – Rockwell Automation 284G ArmorStart - User Manual User Manual
Page 247

Bulletin 280G/281G CIP Information
B-23
The following common services are implemented for the Control
Supervisor Object:
Table B.53 Control Supervisor Object Common Services
Acknowledge Handler Object —
CLASS CODE 0x002b
No class attributes are supported for the Acknowledge Handler
Object.
A single instance (instance 1) of the Acknowledge Handler Object is
supported. The following instance attributes are supported:
Table B.54 Acknowledge Handler Instance Attributes
The following common services are implemented for the
Acknowledge Handler Object:
Table B.55 Acknowledge Handler Common Services
Service Code
Implemented for:
Service Name
Class
Instance
0x0E
No
Yes
Get_Attribute_Single
0x10
No
Yes
Set_Attribute_Single
Attribute ID
Access Rule
Name
Data Type
Value
1
Get/Set
Acknowledge Timer
UINT
milliseconds
2
Get
Retry Limit
USINT
1
3
Get
COS Producing Connection
Instance
UINT
4
Service Code
Implemented for:
Service Name
Class
Instance
0x0E
No
Yes
Get_Attribute_Single
0x10
No
Yes
Set_Attribute_Single