Discrete output group object — class code 0x001e – Rockwell Automation 284G ArmorStart - User Manual User Manual
Page 245

Bulletin 280G/281G CIP Information
B-21
Discrete Output Group Object —
CLASS CODE 0x001E
No class attributes are supported for the Discrete Output Group
Object.
A single instance of the Discrete Output Group Object is supported. It
contains the following attributes:
Table B.50 Discrete Output Instance Attributes
The following common services are implemented for the Discrete
Output Group Object:
Table B.51 Discrete Output Group Common Services
Attribute ID
Access Rule
Name
Data Type
Value
3
Get
Number of Instances
USINT
4 for DOL
4
Get
Binding
Array of UINT
List of DOP instances; 1, 2, 3, 4
6
Get/Set
Command
BOOL
0=idle; 1=run
104
Get/Set
Network Status Override
BOOL
0=No Override (go to safe state)
1=Override (run local logic)
105
Get/Set
Comm Status Override
BOOL
0=No override (go to safe state)
1=Override (run local logic)
Service Code
Implemented for:
Service Name
Class
Instance
0x0E
No
Yes
Get_Attribute_Single
0x10
No
Yes
Set_Attribute_Single