Rockwell Automation 284G ArmorStart - User Manual User Manual
Page 235

Bulletin 280G/281G CIP Information
B-11
Instance 2 is the Predefined Group 2 Connection Set Polled I/O
Message Connection. The following instance 2 attributes are
supported:
Table B.31 Connection Object Instance 2 Attributes
Attribute ID
Access Rule
Name
Data Type
Value
1
Get
State
USINT
0=nonexistant
1=configuring
3=established
4=timed out
2
Get
Instance Type
USINT
1= I/O Connection
3
Get
Transport Class Trigger
USINT
0x82 — Server, Transport Class 2
(If alloc_choice != polled and ack suppression is enabled
then value = 0x80)
4
Get
Produced Connection ID
UINT
01111xxxxxx
xxxxxx=node
address
5
Get
Consumed Connection ID
UINT
10xxxxxx101
xxxxxx=node
address
6
Get
Initial Comm Characteristics
USINT
0x21
7
Get
Produced Connection Size
UINT
0 to 8
8
Get
Consumed Connection Size
UINT
0 to 8
9
Get/Set
Expected Packet Rate
UINT
in ms
12
Get/Set
Watchdog Action
USINT
0=transition to timed out
1=auto delete
2=auto reset
13
Get
Produced Connection Path Length
UINT
8
14
Get/Set
Produced Connection Path
21 04 00 25 (assy inst) 00 30 03
15
Get
Consumed Connection Path Length
UINT
8
16
Get/Set
Consumed Connection Path
21 04 00 25 (assy inst) 00 30 03