13.2

Parameters of the communication module for slot MXI1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.2

Parameters of the communication module for slot MXI1

This chapter lists the parameters of the E94AYCEO communication module (EtherNet/IP) for slot

MXI2 of the Servo Drive 9400 in numerically ascending order.

C13000

C13001

C13002

Parameter | Name:

C13000 | IP address

Data type: UNSIGNED_8

Index: 11575 = 0x2D37

Setting of the IP address

Setting the IP configuration of the Servo Drive 9400 ( 37)

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C13000/1

192

IP address (most significant byte)

C13000/2

168

IP address

C13000/3

124

IP address

C13000/4

16

IP address (least significant byte)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13001 | Subnetwork Mask

Data type: UNSIGNED_8

Index: 11574 = 0x2D36

Setting of the subnet mask

Setting the IP configuration of the Servo Drive 9400 ( 37)

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C13001/1

255

Subnet mask (most significant byte)

C13001/2

255

Subnet mask

C13001/3

255

Subnet mask

C13001/4

0

Subnet mask (least significant byte)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13002 | Gateway address

Data type: UNSIGNED_8

Index: 11573 = 0x2D35

Setting of the gateway address

Setting the IP configuration of the Servo Drive 9400 ( 37)

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C13002/1

0

Gateway address (most significant byte)

C13002/2

0

Gateway address

C13002/3

0

Gateway address

C13002/4

0

Gateway address (least significant byte)