Establishing an online connection via EtherNet/IP with the Lenze »Engineer«
45
Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
In the »Engineer«, you can use the Online Set communication path and go online menu
command to select the EtherNet/IP communication path. The previously configured EtherNet/IP
nodes are shown in the "Communication path" dialog window:
If the device access path is not configured correctly, the
IP address of the drive selected in the
display field can be entered manually here.
Via the
Search/Enter button, you can establish a connection to devices which have not
appeared in the display field. Corresponding settings for this can be made in the "Enter IP Address"
dialog window that will appear:
Here you can enter an
IP address manually or execute the following actions using the buttons:
• Execute the console command
Ping.
• Assign the IP address via the
Configurator.
Setting via the EtherNet/IP configurator of the »Engineer«
• Select the device access path to the desired drive by clicking
Find.
After having established the online connection, you can continue work with the »Engineer« as
usual.