beautypg.com

6commissioning – Lenze E94AYCEO User Manual

Page 38

background image

Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17

38

6

Commissioning

6.3

Setting the IP configuration of the Servo Drive 9400

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3.1

Setting via the EtherNet/IP configurator of the »Engineer«

How to set the IP parameters via the EtherNet/IP configurator:

1. Execute the menu command Online PROFINET /EtherNet/IP configurator addresses ....

The Assign IP addresses dialog window is opened and all Lenze EtherNet/IP nodes

connected are listed.

Note!

• Changes in the IP parameters will become effective immediately.
• An existing IP connection to the Servo Drive 9400 will be interrupted.
• This procedure cannot be applied if the network is configured by a BOOTP/DHCP

server.

Setting via a BOOTP/DHCP server

( 42)

(

C13005

/

C14005

)