C14016 | active multicast ip address, C14017 | ethernet config control, C14016 – Lenze E94AYCEO User Manual
Page 106: C14016/1, C14016/2, C14016/3, C14016/4, 13 parameter reference
Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17
106
13
Parameter reference
13.3
Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14016
C14017
Parameter | Name:
C14016 | Active Multicast IP Address
Data type: UNSIGNED_8
Index: 10559 = 0x293F
Display of the active multicast IP address
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C14016/1
Multicast IP address (most significant byte)
C14016/2
Multicast IP address
C14016/3
Multicast IP address
C14016/4
Multicast IP address (least significant byte)
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14017 | Ethernet Config Control
Data type: UNSIGNED_16
Index: 10558 = 0x293E
Setting of the baud rate for the Ethernet connections
• Depending on the configuration of the Ethernet port of the device to be connected, we recommend the use of a
cross-over cable.
• After changing the setting, carry out a "Type 0 Reset" for the
Identity Object (1 / 0x01) ( 121)
of the node or
switch off and on the voltage supply of the communication module.
Selection list
0 Auto-Negotiation
1 Reserved
2 Reserved
3 Reserved
4 Reserved
5 10 Mbps/Half Duplex
6 10 Mbps/Full Duplex
7 100 Mbps/Half Duplex
8 100 Mbps/Full Duplex
9 Reserved
10 Reserved
11 Reserved
12 Reserved
Subcodes
Lenze setting
Info
C14017/1
0: Auto-Negotiation
Ethernet setting port X233
C14017/2
0: Auto-Negotiation
Ethernet setting port X234
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT