Menu flow chart, 79 echo acp configuration manual – ETC Echo Architectural Control Processor (ACP) v1.0.0 User Manual
Page 84
79
Echo ACP Configuration Manual
Menu Flow Chart
Note:
Note:
Space 1:
2
Space 2:
1, 16
Space 5:
5-7, 16
Space 6:
5-7, 16
Space 7:
5-7, 16
Space 8:
None
Space 16:
2, 5-7
About
1 About Dimmer
2 Level Summary
3 Version Info
4 Space Combine
Version Info
Space Combine
Echo ACP App:
1.0.0.0.0.0.05
DRd: 1.3.0.9.0.61
FLO: 1.0.1.9.0.22
Echo Protocol:
1.0.0.0.0.123
Echo PHY:
1.1.1.0.1211
When the rack is
a DRd12-48, two racks
display in the list with
appended number 1 or 2.
FLO or DALI version info
displays only when they
are installed.
Shows each dimmer
position of rack, along
with Circuit number, winning
control source, and its
current level.
1 About Dimmer
2 Level Summary
3 Version Info
4 Space Combine
About
Current Level:
100%
DMX Level:
45%
sACN :evel:
0%
Arch Level:
33%
Set Level:
0%
Panic/Emer: 100%
About Dimmer
1
< p u s h E n t e r f o r m o r e >
About Dimmer
1
DMX address:
125
sACN address:
1234/123
Module Type:
D20F
Mode: Fluorescent
Space: Space
1
Current Level:
100%
1 About Dimmer
2 Levels Summary
3 Version Info
4 Space Combine
About
Dim Ckt Src Level
1 1 DMX
255
2 24
sACN
128
3 3 Arch
75
4 4 ---
---
5 5 DMX
255
6 6 Emerg
255
7 7 Set
0
1 About Dimmer
2 Level Summary
3 Version Info
4 Space Combine
About
Arch Setup
Remote Record
Off
Data Source Settings
Data Loss & Power On
Preferences
Space Setup
Network Settings
Data Source Settings
DMX Input:
Enabled
DMX Priority:
100
Arch Priority:
100
Arch Setup
Remote Record
Off
Data Source Settings
Data Loss & Power On
Preferences
Space Setup
Network Settings
Data Loss Behavior
Mode:
Hold Last Look
Wait Time:
Forever
sACN Loss Behavior
Mode:
Wait and Fade
Wait Time:
3 min 0 sec
Fade Time:
0 min 3 sec
Power On Behavior
Mode: None
Note:
Note:
Specify a
range of dimmers for
dimmer setup. When a range
of dimmers is selected, those
properties that are not equal
display as blank. Edits made to empty
properties apply to all applicable.
The available module type list is
rack voltage dependent. Changing
a module type defaults all
properties for the specified
dimmer(s).
Each
dimmer must have a
Space assignment. By default
this is set to Space 1. The
available Spaces are defined in
the Arch Setup > Space Setup menu.
A maximum of 8 spaces are allowed.
Specify a Zone and Circuit assignment
for each dimmer. Zones are assigned by
default to the first 16 consecutive
dimmers in the same space.
Circuit numbers by default
match the dimmer number.
Module Type:
D20
Mode:
Normal
Curve:
Mod Square
Threshold:
1 %
Voltage Reg:
On
Max Scale:
118 V
Min Scale:
6 V
Dyn Preheat:
Off
Transformer mode:
On
DMX Res:
Hi 16 bit
Space:
1
Zone:
1
Circuit:
1
Name: Circuit
1
Dimmer Setup
Dimming Setup
Dimmer Setup
Patch DMX Input
Patch sACN Input
Emergency Setup
Quick Rack Setup
Push to Set Levels
1
Note:
Specify a
range of dimmers.
Dimmer doubled dimmers
are applied a default +256
offset. Hi and lo resolution
dimmers default a +1 offset.
Uneditable dimmers
display as NA.
Patch DMX Input
1:
111 a
111 b
2: 112
a
368
b
3: NA
4: 113
5: 114
H
115
L
6: 116
a
117
b
Dim DMX
Dimming Setup
Dimmer Setup
Patch DMX Input
Patch sACN Input
Emergency Setup
Quick Rack Setup
Push to Set Levels
Note:
Patch Dimmers
DIM
sACN
Univ
1:
111 a
111 b
63999
2: 112
a
368
b 1
3: NA
4: 113
1
5: 114
H
115
L 1
6: 116
a
117
b 2
Specify a
range of dimmers. Edit
sACN patch data and specify
universe configuration.
Up to four sACN input
universes can be configured
to the dimmers.
Dimming Setup
Dimmer Setup
Patch DMX Input
Patch sACN Input
Emergency Setup
Quick Rack Setup
Push to Set Levels
Note:
Emergency Dimmers
1:
O n
2: O n
3: --
4: O n
5: --
6: --
7: O n
8: O n
9: O n
1 0: --
11: O n
1 2: O n
13: N A
1 4: N A 1 5 A : O n
1 5 B:O n 1 6 A :O n 1 6 B:
O n
On is default,
-- =off, NA =dimmer that
is not applicable such as a
CC20 or single density dimmer.
Dimmer doubled dimmers have
“a”&“b” dimmers. Use [and]
and [thru] functions
to select.
Emergency Dimmers
Emergency Level:
100
Load Shedding:
On
Input Type:
Maintained
Active When:
Closed
Emergency Setup
Dimming Setup
Dimmer Setup
Patch DMX Input
Patch sACN Input
Emergency Setup
Quick Rack Setup
Push to Set Levels
Note:
Module
types vary by
operating voltage. Changing
the module type defaults all
dimmer properties.
Apply changed settings* only
or all settings using the
menu options.
Dimmer Setup
Patch DMX Input
Patch sACN Input
Emergency Setup
Quick Rack Setup
Push to Set Levels
Dimming Setup
Voltage L-N:
Auto
Rack Type:
Auto
Module Type:
D20
Balance: Straight
DMX Start Addr:
1
sACN Universe:
1
sACN Start Addr:
1
Space: 1
Temp: Auto
Apply Changes * Only
Apply All
Quick Rack Setup
Dimming Rack Status
System OK
DMX Start = 1
Ш1: 119
Ш2: 119
Ш3: 120
60Hz 102F v1.0.2
Arch Control Status
No Active Preset
IP: 10.101.166.101
System OK
DMX Start = 312
DMX Input: Active
DRd12
v1.2.3
A
A
A
A
A
A
A
A
A
Main Menu
1 About
2 Dimming Setup
3 Arch Setup
4 Dimming Control
5 Arch Control
6 File Operations
7 View/Clear Errors
8 Restricted Access
D
1 About
2 Dimming Setup
3 Arch Setup
4 Dimming Control
5 Arch Control
6 File Operations
7 View/Clear Errors
8 Restricted Access
1 About
2 Dimming Setup
3 Arch Setup
4 Dimming Control
5 Arch Control
6 File Operations
7 View/Clear Errors
8 Restricted Access
Main Menu