Status display, Drd dimming rack status display, N o t e – ETC Echo Architectural Control Processor (ACP) v1.0.0 User Manual
Page 24

19
Echo ACP Configuration Manual
Status Display
The Echo Architectural Control Processor (E-ACP) provides all of the basic rack and
system information on the status display. When the Echo ACP is installed in a DRd
enclosure, the dimming rack status display is the default status display. The architectural
control status display is the only status display available when the Echo ACP is installed in
an ERn enclosure.
DRd Dimming Rack Status Display
•
display title - A menu’s title appears in the first row of every display for easy navigation.
•
scroll to next display - When the clockwise symbol appears in the display, use the
touch wheel to scroll clockwise to the Arch Control Status display. When the counter-
clockwise symbol appears, use the touch wheel to scroll counter-clockwise for the
previous display.
•
Rack Dimmer levels - A DRd enclosure with 1 to 24 channels will display all dimmers
with proportional levels on the line beneath the display title (as pictured above). Cross-
bussed DRd enclosure display dimmers 1-24 on the top line beneath the display title
and dimmers 25-48 on the next line.
•
System Message and Error Display - System messages are common to both the
dimming rack and ACP status displays. When a system error is detected, the message
changes to reflect the specific error type. When multiple errors are detected, each error
message cycles on the display, first by severity and then by chronological occurrence.
Reference
for a complete listing of possible errors and the
actions required to clear them.
•
DMX Start - Indicates the DMX start address of the first circuit in the DRd enclosure.
An equal sign (=) before the address number indicates a 1 to 1 patch of DMX address
to the dimmers in the rack. An approximate equal sign
≈
before the address number
indicates advanced patching. The DMX value is appended with (bal) when the rack is
configured for 3 phase or 1/bi-phase balanced. Reference the
for details on patching.
•
Per Phase Voltage - Each phase of power is measured and represented on the
Dimming Rack Status display. When the rack is configured for bi-phase, only phases 1
and 2 are shown, when the rack is configured for single phase, only the single phase
data is available.
•
Operating Frequency, Temps and Dimming software version- Displays the
measured operating frequency and temperature inside the enclosure, and the installed
version of Dimming software. The temperature is shown in °F by default, but can be set
to °C in the
menu.
N o t e :
Voltage displayed is a user convenience and is approximate. It is not as accurate
as using proper voltage measurement equipment.
Dimming Rack Status
System OK
DMX Start = 155
Ш1: 119
Ш2: 119
Ш3: 120
60Hz 102F
v5.6.7