Specifications
Electrical
100V to 240V
Frequency: 50/60 Hz
Temperature and humidity
10 to 32°C, 15 to 85RH
50 to 90°F, 15 to 85RH
Note
Above 82°F (28°C), reduced humidity is required to maintain the specified performance.
Fault code
Possible cause
Recommended solution
048 100
048 102
048 103
048 900
048 901
048 903
Paper jam
•
A jam occurred during
feeding
•
A jam notification is
displayed on the UI
•
Open the front door.
•
Carefully remove all sheets and paper
scraps from jam clearance areas.
•
Close the front door.
•
Verify the paper used is within the
approved paper specifications.
048 300
The front door is open.
Close the front door.
048 310
048 311
048 312
048 313
048 314
048 315
048 316
Decurler sensor or belt problem
Power off, then power on
048 318
048 319
Cooling fan failure
Power off, then power on
048 320
048 321
048 322
Communication failure or
connection failure
•
Check the connection between Interface
Module and the finishing device.
•
Power off, then power on.
048 323
Interface Module failure
Power off, then power on