Using the i1 spectrophotometer to measure a color chart
and create a profile
Requirements:
●
The press must already be calibrated.
●
The i1 spectrophotometer must be placed on its base and
connected to the USB port on the IC-309 print controller.
1. From the Tools menu, select Profiling Tool.
2. Select Print and measure chart.
3. Click Next.
4. Perform the following actions:
a. In the Measuring device list, select the i1
spectrophotometer as the measuring device that you will
use to measure the color chart.
b. In the Warm up copies box, select the number of copies of
the warm-up file that you want to print.
c. In the Tray list, select the tray in which the paper stock for
which you want to create a profile is loaded.
d. In the Screening list, select the screening method for the
profile.
e. In the Calibration list, select the relevant calibration table.
Latest is the default setting (highly recommended).
f. In the Number of copies box, select the number of copies
of the chart that you want to print.
5. Click Print.
The color measurement chart and the warm-up file are
printed.
6. Place the color measurement chart on a clean flat surface.
7. Click Measure and perform the following actions.
a. Press the button located on the measurement device.
b. When you hear a beep, scan the device across strip 1 in
the following manner:
Note: To avoid measurement failures, perform the following steps to
scan the strip:
Using the i1 spectrophotometer to measure a color chart and create a profile