Calibration table info graph tab – Konica Minolta bizhub PRESS C1060 User Manual
Page 100
This tab includes the following:
●
Output Density
Measured
The values that are measured from the printed target.
Target
The expected values of the output density.
Minimum Accepted
The minimum measured value of the output density that
is accepted for correction.
●
Properties—The parameters selected when the calibration
table was created.
Calibration table Info Graph tab
During printing, the IC-309 print controller automatically replaces
the CMYK values in the RTP file with new values that compensate
for the printer’s current performance level.
This tab includes the following:
Separations
The graph displays cyan, magenta, yellow, and black
separations. You can view information about each
separation by clicking the desired separation button, or you
90
Chapter 7—Managing color